3/5/12 Lead ECG Board for Patient Monitor
US$100.00 - 500.00 | 100 Pieces (MOQ) |
Port:
Shenzhen, China
Production Capacity:
100000
Payment Terms:
L/C, T/T, Western Union, Paypal
Guangdong, China
Last Login Date:
Aug 08, 2025
Main Products:
Patient Monitor, Multi-Parameter Patient Monitor, Multipara Patient Monitor, Portable Patient Monitor, Pulse Oximeter, Handheld Pulse Oximeter, Fingertip Pulse Oximeter, Fetal Doppler, Fetal Monitor, Vital Signs Monitor
Find Similar Products
Product Description
Company Info
Basic Info.
Model NO.
AC-001
Classification
Physiological Functions of Diagnosis and Monitoring Equipment
Type
Certification
Lead Mode
3/5/12 Lead ECG for Optional
Trademark
Sinnor
Transport Package
Carton Bag
Specification
Origin
Shenzhen, China
Product Description
Lead mode: 5 -lead(R, L, F, N, C) (3/12 lead ECG for optional)
Lead selection: I, II, III, avR, avL, avF, V
Waveform: 3 and 7 channel selectable
Gain selection: 0.5mm/mv,1mm/mv,2mm/mv
Sweep speed: 6.25mm/s;12.5mm/s;25mm/s;50mm/s
Heart rate range: Adult: 15~300bpm;
Neonate/pediatric: 15~350bpm
Accuracy: +1bpm or +1%, which is greater
Resolution: 1bpm
Filter: surgery mode: 1~20Hz
Monitor model: 0.5~40Hz
Diagnostic mode: 0.05~130Hz
Scaling signal: 1mv, +3%
Protection: withstand 4000VAC/50 voltage isolation against electrosurgical interference and defibrillation
Alarm range: 15~350bpm
S-T segment detection:
Measurement range: 2.0mV~+2.0mV
Alarm Range: -2.0mV~ +2.0mV
Accuracy: -0.8mV ~+0.8Mv
Error: +0.02Mv
Arrhythmia analysis: YES
Parameter Specification
ECG |
Lead mode: 5 -lead(R, L, F, N, C) (3/12 lead ECG for optional) Lead selection: I, II, III, avR, avL, avF, V Waveform: 3 and 7 channel selectable Gain selection: 0.5mm/mv,1mm/mv,2mm/mv Sweep speed: 6.25mm/s;12.5mm/s;25mm/s;50mm/s Heart rate range: Adult: 15~300bpm; Neonate/pediatric: 15~350bpm Accuracy: +1bpm or +1%, which is greater Resolution: 1bpm Filter: surgery mode: 1~20Hz Monitor model: 0.5~40Hz Diagnostic mode: 0.05~130Hz Scaling signal: 1mv, +3% Protection: withstand 4000VAC/50 voltage isolation against electrosurgical interference and defibrillation Alarm range: 15~350bpm S-T segment detection: Measurement range: 2.0mV~+2.0mV Alarm Range: -2.0mV~ +2.0mV Accuracy: -0.8mV ~+0.8Mv Error: +0.02Mv Arrhythmia analysis: YES |
SPO2 |
Measurement range: 0~100% Wave speed: 12.5mm/s;25mm/s Resolution: 1% Accuracy: +2% (70-100%); 0-69% unspecified Alarm range 0~100% Lower perfusion situation |
Pulse Rate(PR) |
Range: 20~300bpm Resolution: 1bpm Error: +1bpm or +2%, whichever is greater |
NIBP |
Method: Digital Automatic oscillometric Operation mode : Manual/Automatic Auto measurement time: Adjustable (1~720min) (1,2,3,4,5,10,15,30,60,90,120,240,480,720min) Measurement Unit: mmHg/Kpa selectable Measurement types: Systolic, Diastolic, Mean Measurement Range: Range of Systolic pressure: Adult: 40~270mmHg Pediatric: 40~220mmHg Neonate: 40~135mmHg Range of mean pressure: Adult: 20~235mmHg Pediatric: 20~165mmHg Neonate: 20~110mmHg Range of diastolic pressure: Adult: 10~215mmHg Pediatric: 10~150mmHg Neonate: 10~100mmHg Over-pressure protection: Double safety protection Resolution: 1 mmHg Alarm: Systolic, Diastolic, and Mean |
RESPIRATION |
Method: RA-LL impedance Measurement range: Adult: 7~120rpm; Neonate/Pediatric: 7~150rpm Apnea alarm: YES, 10~40s Resolution: 1rpm Accuracy: +2rpm |
TEMPERATURE |
Compatible probe: YSI or CYF Measurement range: 5~50ºC Resolution: 0.1ºC Accuracy: +0.1ºC Refreshing time: about 1 Average measuring time: <10s |