ECG Board for Portable Patient Monitor (AC-001)

Product Details
Customization: Available
Classification: Physiological Functions of Diagnosis and Monitoring Equipment
Type: Patient Monitor
Gold Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Years of Export Experience
The export experience of the supplier is more than 10 years
Self-branded
The supplier has 2 Self-brands, check the Audit Report for more information
Fast Delivery
The supplier can deliver the goods within 15 days
OEM Services
The supplier provides OEM services for popular brands
to see all verified strength labels (21)
Find Similar Products

Basic Info.

Model NO.
AC-001
Certification
ISO13485
Lead Mode
3/5/12 Lead ECG for Optional
Transport Package
Carton Bag
Specification
ISO13485
Trademark
Sinnor
Origin
Shenzhen, China
Production Capacity
100000

Product Description

Lead mode:                                5 –lead(R, L, F, N, C) (3/12 lead ECG for optional)
Lead selection:                          I, II, III, avR, avL, avF, V
Waveform:                          3 and 7 channel selectable
Gain selection:                         0.5mm/mv,1mm/mv,2mm/mv
Sweep speed:                          6.25mm/s;12.5mm/s;25mm/s;50mm/s
Heart rate range:                        Adult: 15~300bpm;
Neonate/pediatric: 15~350bpm
Accuracy:                                   +1bpm or +1%, which is greater
Resolution:                          1bpm
Filter:                                            surgery mode: 1~20Hz
Monitor model: 0.5~40Hz
Diagnostic mode: 0.05~130Hz
Scaling signal:                           1mv, +3%
Protection:                         withstand 4000VAC/50 voltage isolation against electrosurgical interference and defibrillation
Alarm range:                             15~350bpm
S-T segment detection:                 
Measurement range:    2.0mV~+2.0mV                         
 Alarm Range:          -2.0mV~ +2.0mV
Accuracy:              -0.8mV ~+0.8Mv
Error:                 +0.02Mv
 
Arrhythmia analysis:         YES 



Parameter Specification

ECG
Lead mode:                                5 –lead(R, L, F, N, C) (3/12 lead ECG for optional)
Lead selection:                          I, II, III, avR, avL, avF, V
Waveform:                          3 and 7 channel selectable
Gain selection:                         0.5mm/mv,1mm/mv,2mm/mv
Sweep speed:                          6.25mm/s;12.5mm/s;25mm/s;50mm/s
Heart rate range:                        Adult: 15~300bpm;
Neonate/pediatric: 15~350bpm
Accuracy:                                   +1bpm or +1%, which is greater
Resolution:                          1bpm
Filter:                                            surgery mode: 1~20Hz
Monitor model: 0.5~40Hz
Diagnostic mode: 0.05~130Hz
Scaling signal:                           1mv, +3%
Protection:                         withstand 4000VAC/50 voltage isolation against electrosurgical interference and defibrillation
Alarm range:                             15~350bpm
S-T segment detection:                 
Measurement range:    2.0mV~+2.0mV                         
 Alarm Range:          -2.0mV~ +2.0mV
Accuracy:              -0.8mV ~+0.8Mv
Error:                 +0.02Mv
 
Arrhythmia analysis:         YES
SPO2
Measurement range:        0~100%
Wave speed:               12.5mm/s;25mm/s
Resolution:                1%
Accuracy:                 +2% (70-100%); 0-69% unspecified
Alarm range               0~100%
Lower perfusion situation
 
Pulse Rate(PR)
Range:                 20~300bpm
Resolution:             1bpm
Error:                 +1bpm or +2%, whichever is greater
 
NIBP
Method:                   Digital Automatic oscillometric
Operation mode :            Manual/Automatic
Auto measurement time:      Adjustable (1~720min)
                          (1,2,3,4,5,10,15,30,60,90,120,240,480,720min)
Measurement Unit:          mmHg/Kpa selectable
Measurement types:         Systolic, Diastolic, Mean 
Measurement Range:
Range of Systolic pressure:    Adult: 40~270mmHg
Pediatric: 40~220mmHg
Neonate: 40~135mmHg
Range of mean pressure:      Adult: 20~235mmHg
Pediatric: 20~165mmHg
Neonate: 20~110mmHg
Range of diastolic pressure:    Adult: 10~215mmHg
Pediatric: 10~150mmHg
Neonate: 10~100mmHg
Over-pressure protection:     Double safety protection
Resolution:                 1 mmHg
Alarm:                     Systolic, Diastolic, and Mean
 
RESPIRATION
Method:                     RA-LL impedance
Measurement range:           Adult: 7~120rpm;
Neonate/Pediatric: 7~150rpm
Apnea alarm:                 YES, 10~40s
Resolution:                   1rpm
Accuracy:                    +2rpm
 
TEMPERATURE
Compatible probe:             YSI or CYF
Measurement range:           5~50ºC
Resolution:                   0.1ºC
Accuracy:                    +0.1ºC
Refreshing time:               about 1
Average measuring time:        <10s
 