• 15inch Plastic Case for Patient Monitor
  • 15inch Plastic Case for Patient Monitor
  • 15inch Plastic Case for Patient Monitor
  • 15inch Plastic Case for Patient Monitor
  • 15inch Plastic Case for Patient Monitor
  • 15inch Plastic Case for Patient Monitor

15inch Plastic Case for Patient Monitor

Transport Package: Carton Bag
Specification: ISO13485
Trademark: Sinnor
Origin: Shenzhen, China
Customization:
Manufacturer/Factory
Gold Member Since 2015

Suppliers with verified business licenses

Guangdong, China
to see all verified strength labels (21)

Basic Info.

Model NO.
SNP8000M
Production Capacity
10000

Product Description

Plastic Case for 15inch Patient Monitor

This plastic case can use for 15inch patient monitor, and it including back case, front case, and all the accessories.
15inch Plastic Case for Patient Monitor
15inch Plastic Case for Patient Monitor
15inch Plastic Case for Patient Monitor
15inch Plastic Case for Patient Monitor
15inch Plastic Case for Patient Monitor
 
Parameter Specification
ECG
Lead mode:                                5 -lead(R, L, F, N, C) (3/12 lead ECG for optional)
Lead selection:                          I, II, III, avR, avL, avF, V
Waveform:                          3 and 7 channel selectable
Gain selection:                         0.5mm/mv,1mm/mv,2mm/mv
Sweep speed:                          6.25mm/s;12.5mm/s;25mm/s;50mm/s
Heart rate range:                        Adult: 15~300bpm;
Neonate/pediatric: 15~350bpm
Accuracy:                                   +1bpm or +1%, which is greater
Resolution:                          1bpm
Filter:                                            surgery mode: 1~20Hz
Monitor model: 0.5~40Hz
Diagnostic mode: 0.05~130Hz
Scaling signal:                           1mv, +3%
Protection:                         withstand 4000VAC/50 voltage isolation against electrosurgical interference and defibrillation
Alarm range:                             15~350bpm
S-T segment detection:                 
Measurement range:    2.0mV~+2.0mV                         
 Alarm Range:          -2.0mV~ +2.0mV
Accuracy:              -0.8mV ~+0.8Mv
Error:                 +0.02Mv
 
Arrhythmia analysis:         YES
SPO2
Measurement range:        0~100%
Wave speed:               12.5mm/s;25mm/s
Resolution:                1%
Accuracy:                 +2% (70-100%); 0-69% unspecified
Alarm range               0~100%
Lower perfusion situation
 
Pulse Rate(PR)
Range:                 20~300bpm
Resolution:             1bpm
Error:                 +1bpm or +2%, whichever is greater
 
NIBP
Method:                   Digital Automatic oscillometric
Operation mode :            Manual/Automatic
Auto measurement time:      Adjustable (1~720min)
                          (1,2,3,4,5,10,15,30,60,90,120,240,480,720min)
Measurement Unit:          mmHg/Kpa selectable
Measurement types:         Systolic, Diastolic, Mean 
Measurement Range:
Range of Systolic pressure:    Adult: 40~270mmHg
Pediatric: 40~220mmHg
Neonate: 40~135mmHg
Range of mean pressure:      Adult: 20~235mmHg
Pediatric: 20~165mmHg
Neonate: 20~110mmHg
Range of diastolic pressure:    Adult: 10~215mmHg
Pediatric: 10~150mmHg
Neonate: 10~100mmHg
Over-pressure protection:     Double safety protection
Resolution:                 1 mmHg
Alarm:                     Systolic, Diastolic, and Mean
 
RESPIRATION
Method:                     RA-LL impedance
Measurement range:           Adult: 7~120rpm;
Neonate/Pediatric: 7~150rpm
Apnea alarm:                 YES, 10~40s
Resolution:                   1rpm
Accuracy:                    +2rpm
 
TEMPERATURE
Compatible probe:             YSI or CYF
Measurement range:           5~50ºC
Resolution:                   0.1ºC
Accuracy:                    +0.1ºC
Refreshing time:               about 1
Average measuring time:        <10s
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2015

Suppliers with verified business licenses

Manufacturer/Factory
Number of Employees
12
Year of Establishment
2007-05-21