Sinnor Patient Monitor Accessories Neonate SpO2 Sensor Wrape Style

Classification: Physiological Functions of Diagnosis and Monitoring Equipment
Type: Patient Monitor
Certification: CE, ISO13485
Color: Gray
Size: 0.9m
Transport Package: Carton
Customization:
Manufacturer/Factory
Gold Member Since 2015

Suppliers with verified business licenses

Guangdong, China
to see all verified strength labels (21)
  • Overview
  • Product Description
  • Detailed Photos
Overview

Basic Info.

Specification
ISO13485
Trademark
Sinnor
Origin
Shenzhen, China
HS Code
9018193000
Production Capacity
5000PCS/Year

Product Description

Sinnor multi-para monitor accessories neonate SPO2 sensor wrape style

Product Description

 

Product performance:

SpO2 oxygen saturation test range: 70% - 100%; SpO2 oxygen saturation measurement accuracy: 90% - 100% ± 2%, 70% - 89% ± 3%;

Pulse rate measurement range: 30 ~ 245 BPM; pulse rate measurement accuracy: ± 3 bpm;

Maximum output power: 2 MW;

4. Scope of application: the encapsulated oxygen probe for newborns can be used for supporting pulse oximeter and multi parameter monitor, continuously and non invasively collect and transmit pulse and oxygen saturation signals of patients (0.5-4kg newborns; 3-15kg infants; 10-40kg children; adults > 40kg); it is not suitable for weak perfusion state and exercise state monitoring, and the probe is not suitable for long-term monitoring, Check every 4 hours or change a finger to measure

5. Contraindications: it is not allowed to fix the blood oxygen probe in patients with tissue damage; it is not suitable for patients and users allergic to PVC, TPU and silicone plastic;

6. Precautions:

A) When choosing the placement site of the wrapped blood oxygen probe, priority should be given to the limb without arterial catheter, blood pressure cuff and venous input tube.

B) If the blood oxygen probe can not accurately monitor the pulse beat, it indicates that its position is not appropriate or the position where it is placed is too thick, too thin or too deep pigment to achieve the appropriate light transmission effect. If this happens, replace the sensor or select another type of sensor.

C) The blood oxygen probe is used in special medical instruments. The operator is responsible for checking whether it is compatible. Incompatible accessories or equipment will affect the test results

D) After the blood oxygen probe is removed from the human body, data and waveform may still be displayed on the monitor or oximeter due to external light interference, which does not mean that the probe is faulty, but the value displayed at this time can not be used as the basis for clinical diagnosis.

7. Warning:

A) Improper use will lead to inaccurate measurement;

B) When the light is too strong, it will lead to inaccurate measurement. In case of any situation, a piece of opaque material should be used to block the light around the sensor.

C) The blood oxygen probe should be moved to a new position at least every 4 hours. Because the local skin condition will affect the skin's ability to bear the probe placement, it is necessary to change the sensor position frequently according to the situation of some patients. If the integrity of the skin changes, the blood oxygen probe should be moved to another part.

D) The dye in the blood vessel can lead to inaccurate measurement.

E) The performance of blood oxygen probe is easily affected by activity, so it is not suitable for active patients.

F) Do not strap the probe or tie it to death, as the pulse of the vein will cause inaccurate saturation measurement.

G) As with other medical equipment, the cable should be placed to avoid winding or suffocating the patient.

H) Do not use during MRI scan. Because the electric current of the conductor can cause burns. Moreover, the blood oxygen probe will affect the MRI image, and the MRI device will also affect the accuracy of blood oxygen measurement.

1) Please do not change or modify this product at will. Because it will affect its performance or accuracy.

J) Do not disinfect with rays, steam or ethylene oxide;

K) Do not immerse the product in liquid for cleaning and disinfection.

50) Mobile phone or mobile RF communication equipment will affect the operation of the sensor


 

Detailed Photos


Sinnor Patient Monitor Accessories Neonate SpO2 Sensor Wrape StyleSinnor Patient Monitor Accessories Neonate SpO2 Sensor Wrape StyleSinnor Patient Monitor Accessories Neonate SpO2 Sensor Wrape StyleSinnor Patient Monitor Accessories Neonate SpO2 Sensor Wrape StyleSinnor Patient Monitor Accessories Neonate SpO2 Sensor Wrape Style

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2015

Suppliers with verified business licenses

Manufacturer/Factory
Number of Employees
12
Year of Establishment
2007-05-21