Main Board for Multi- Parameter Patient Monitor

Classification: Physiological Functions of Diagnosis and Monitoring Equipment
Type: Patient Monitor
Certification: ISO13485
Transport Package: Carton Bag
Specification: ISO13485
Trademark: Sinnor
Customization:
Manufacturer/Factory
Gold Member Since 2015

Suppliers with verified business licenses

Rating: 5.0/5
Guangdong, China
Years of Export Experience
The export experience of the supplier is more than 10 years
Self-branded
The supplier has 1 Self-brands, check the Audit Report for more information
Fast Delivery
The supplier can deliver the goods within 15 days
OEM Services
The supplier provides OEM services for popular brands
to see all verified strength labels (21)

Basic Info.

Model NO.
AC-002
Origin
Shenzhen, China
Production Capacity
100000

Product Description

Advance patient Manage: gender, full name, ID no., room no., bed no.,  weight, height, blood type, paced or not, remakes; Multi-parameter board: Separated parameter board, main board, ECG board, SPO2 board, and NIBP board are independent; Interface: Color, layout of each parameters can be set up by user need, bed to bed view display(optional); Fanless: Use special fanless cooling technology in the device to provide users quiet environment; Standby: Unique standby mode for energy saving and suspend monitoring; Time delay: Time delay switch-off function to save data when monitor turn off suddenly; Easy software update: Users can update monitor software by themselves; Analysis: Real time S-T segment analysis, and 20 type arrhythmic analysis; SpO2 Pitch Tone Variation, Drug Dose Calculation and Hemodynamic Calculations; Storage: external SD card slot enables memory extension(optional); Data transfer: USB port to allow to transfer patient data to a PC (optional); Special SINNOR F-6 Spo2 technology: which is as correct as Nellcor spo2 but cheaper than it(optional);   Resistance to interference : Efficient resistance to interference of defibrillator and HF knife; Other optional: Touch Screen, Printer, Wall amount, VGA connect Parameter Specification ECG Lead mode:                                5 –lead(R, L, F, N, C) (3/12 lead ECG for optional) Lead selection:                          I, II, III, avR, avL, avF, V Waveform:                          3 and 7 channel selectable Gain selection:                         0.5mm/mv,1mm/mv,2mm/mv Sweep speed:                          6.25mm/s;12.5mm/s;25mm/s;50mm/s Heart rate range:                        Adult: 15~300bpm; Neonate/pediatric: 15~350bpm Accuracy:                                   +1bpm or +1%, which is greater Resolution:                          1bpm Filter:                                            surgery mode: 1~20Hz Monitor model: 0.5~40Hz Diagnostic mode: 0.05~130Hz Scaling signal:                           1mv, +3% Protection:                         withstand 4000VAC/50 voltage isolation against electrosurgical interference and defibrillation Alarm range:                             15~350bpm S-T segment detection:                   Measurement range:    2.0mV~+2.0mV                         Alarm Range:          -2.0mV~ +2.0mV Accuracy:              -0.8mV ~+0.8Mv Error:                 +0.02Mv Arrhythmia analysis:         YES SPO2 Measurement range:        0~100% Wave speed:               12.5mm/s;25mm/s Resolution:                1% Accuracy:                 +2% (70-100%); 0-69% unspecified Alarm range               0~100% Lower perfusion situation Pulse Rate(PR) Range:                 20~300bpm Resolution:             1bpm Error:                 +1bpm or +2%, whichever is greater NIBP Method:                   Digital Automatic oscillometric Operation mode :            Manual/Automatic Auto measurement time:      Adjustable (1~720min)                           (1,2,3,4,5,10,15,30,60,90,120,240,480,720min) Measurement Unit:          mmHg/Kpa selectable Measurement types:         Systolic, Diastolic, Mean   Measurement Range: Range of Systolic pressure:    Adult: 40~270mmHg Pediatric: 40~220mmHg Neonate: 40~135mmHg Range of mean pressure:      Adult: 20~235mmHg Pediatric: 20~165mmHg Neonate: 20~110mmHg Range of diastolic pressure:    Adult: 10~215mmHg Pediatric: 10~150mmHg Neonate: 10~100mmHg Over-pressure protection:     Double safety protection Resolution:                 1 mmHg Alarm:                     Systolic, Diastolic, and Mean RESPIRATION Method:                     RA-LL impedance Measurement range:           Adult: 7~120rpm; Neonate/Pediatric: 7~150rpm Apnea alarm:                 YES, 10~40s Resolution:                   1rpm Accuracy:                    +2rpm TEMPERATURE Compatible probe:             YSI or CYF Measurement range:           5~50ºC Resolution:                   0.1ºC Accuracy:                    +0.1ºC Refreshing time:               about 1 Average measuring time:        <10s

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2015

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory
Number of Employees
12
Year of Establishment
2007-05-21