消息
×
loading..
x

Main Board for Multi- Parameter Patient Monitor

US$100.00 - 200.00 100 Pieces (MOQ)
Port:
Shenzhen, China
Production Capacity:
100000
Payment Terms:
L/C, T/T, Western Union

Sinnor Instruments, Inc.

Guangdong, China

Rating: 5.0/5

Last Login Date:

Aug 04, 2025

Main Products:

Patient Monitor, Multi-Parameter Patient Monitor, Multipara Patient Monitor, Portable Patient Monitor, Pulse Oximeter, Handheld Pulse Oximeter, Fingertip Pulse Oximeter, Fetal Doppler, Fetal Monitor, Vital Signs Monitor

Find Similar Products
Negotiable
1 Piece (MOQ)
US$100.00-300.00
10 Pieces (MOQ)

Product Description

Company Info

Basic Info.

Model NO.
AC-002
Classification
Physiological Functions of Diagnosis and Monitoring Equipment
Type
Patient Monitor
Certification
ISO13485
Trademark
Sinnor
Transport Package
Carton Bag
Specification
ISO13485
Origin
Shenzhen, China

Product Description

Advance patient Manage: gender, full name, ID no., room no., bed no.,  weight, height, blood type, paced or not, remakes;
Multi-parameter board: Separated parameter board, main board, ECG board, SPO2 board, and NIBP board are independent;
Interface: Color, layout of each parameters can be set up by user need, bed to bed view display(optional);
Fanless: Use special fanless cooling technology in the device to provide users quiet environment;
Standby: Unique standby mode for energy saving and suspend monitoring;
Time delay: Time delay switch-off function to save data when monitor turn off suddenly;
Easy software update: Users can update monitor software by themselves;
Analysis: Real time S-T segment analysis, and 20 type arrhythmic analysis; SpO2 Pitch Tone Variation, Drug Dose Calculation and Hemodynamic Calculations;
Storage: external SD card slot enables memory extension(optional);
Data transfer: USB port to allow to transfer patient data to a PC (optional);
Special SINNOR F-6 Spo2 technology: which is as correct as Nellcor spo2 but cheaper than it(optional);  
Resistance to interference : Efficient resistance to interference of defibrillator and HF knife;
Other optional: Touch Screen, Printer, Wall amount, VGA connect
Parameter Specification

ECG
Lead mode:                                5 -lead(R, L, F, N, C) (3/12 lead ECG for optional)
Lead selection:                          I, II, III, avR, avL, avF, V
Waveform:                          3 and 7 channel selectable
Gain selection:                         0.5mm/mv,1mm/mv,2mm/mv
Sweep speed:                          6.25mm/s;12.5mm/s;25mm/s;50mm/s
Heart rate range:                        Adult: 15~300bpm;
Neonate/pediatric: 15~350bpm
Accuracy:                                   +1bpm or +1%, which is greater
Resolution:                          1bpm
Filter:                                            surgery mode: 1~20Hz
Monitor model: 0.5~40Hz
Diagnostic mode: 0.05~130Hz
Scaling signal:                           1mv, +3%
Protection:                         withstand 4000VAC/50 voltage isolation against electrosurgical interference and defibrillation
Alarm range:                             15~350bpm
S-T segment detection:                  
Measurement range:    2.0mV~+2.0mV                        
Alarm Range:          -2.0mV~ +2.0mV
Accuracy:              -0.8mV ~+0.8Mv
Error:                 +0.02Mv

Arrhythmia analysis:         YES
SPO2
Measurement range:        0~100%
Wave speed:               12.5mm/s;25mm/s
Resolution:                1%
Accuracy:                 +2% (70-100%); 0-69% unspecified
Alarm range               0~100%
Lower perfusion situation

Pulse Rate(PR)
Range:                 20~300bpm
Resolution:             1bpm
Error:                 +1bpm or +2%, whichever is greater

NIBP
Method:                   Digital Automatic oscillometric
Operation mode :            Manual/Automatic
Auto measurement time:      Adjustable (1~720min)
                          (1,2,3,4,5,10,15,30,60,90,120,240,480,720min)
Measurement Unit:          mmHg/Kpa selectable
Measurement types:         Systolic, Diastolic, Mean  
Measurement Range:
Range of Systolic pressure:    Adult: 40~270mmHg
Pediatric: 40~220mmHg
Neonate: 40~135mmHg
Range of mean pressure:      Adult: 20~235mmHg
Pediatric: 20~165mmHg
Neonate: 20~110mmHg
Range of diastolic pressure:    Adult: 10~215mmHg
Pediatric: 10~150mmHg
Neonate: 10~100mmHg
Over-pressure protection:     Double safety protection
Resolution:                 1 mmHg
Alarm:                     Systolic, Diastolic, and Mean

RESPIRATION
Method:                     RA-LL impedance
Measurement range:           Adult: 7~120rpm;
Neonate/Pediatric: 7~150rpm
Apnea alarm:                 YES, 10~40s
Resolution:                   1rpm
Accuracy:                    +2rpm

TEMPERATURE
Compatible probe:             YSI or CYF
Measurement range:           5~50ºC
Resolution:                   0.1ºC
Accuracy:                    +0.1ºC
Refreshing time:               about 1